KEPKEP |
® |
|
SPT 01 |
|
![]() |
![]() |
ADSL POTS Splitter Unit designed by
Kepkep Company. ADSL POTS splitter is
implemented with the Voice Band
Passing LOW pass filter to stabile
separate voice signal from the
composite band Asymmetrical Digital
Subscriber Line (ADSL) data and voice.
ADSL POTS Splitter protects POTS from
interference signal, which is caused
by ATU-R Modem and protects ATU-R
Modem from signals related POTS. The
Splitter should keep stable features
with DC loop current 100 mA and keep
balance itself in case of Ring tone.
The filter should be consisted of two
level of low pass filter, which should
be passive structure.
Insertion Loss
The insertion loss at 1KHz of the
single low–pass filter, between the
LINE and POTS interface attenuation
maintain less than 0.3 dB, when the
interfaces are terminated with the
network of which fulfills the ITU-T
G992.1 recommendation clause E.1.3
Insertion Frequency Distortion
The frequency distortion between LINE
and POTS interface, relative to 1KHz,
keep within ±1 dB over the frequency
range from 200Hz to 4KHz. This
fulfills the ITU-T G992.1
recommendation clause E.1.4.
Return Loss
The return loss of the POTS and LINE
interface, measured against the
impedance of the network with the
opposite interface terminated with the
same network, as follows:
200 Hz to 300 Hz with 600 Ohms >12 dB
300 Hz to 500 Hz with 600 Ohms >14 dB
500 Hz to 2000 Hz with 600 Ohms >18 dB
2000 Hz to 3400 Hz with 600 Ohms >14
dB
3400 Hz to 4000 Hz with 600 Ohms >12
dB
This fulfills the ITU-T G992.1
recommendation clause E.1.2.
Stop Band Attenuation
When measured between 100 Ohms
termination and with the normal High–pass
filter load, the stop band attenuation
of the filter is higher than 50 dB
between 32 KHz to 100 KHz.
Isolation
The DC resistance observed at the POTS
interface does not exceed 50 Ohms when
a short circuit is applied across the
LINE interface, and shall not be less
than 1 MOhms in the open circuit
condition. This fulfills the ITUT
G992.1 recommendation clause E.1.5.
Environmental Conditions
Operating temperature: -20º C / +55º C
Operating humidity: % 90 RH
Electrical Safety
There is no lightning and high voltage
protection both at the input side of
the Splitter and at the output side of
the Splitter. Anyway, existing
structure of Main Distribution Room (MDF)
has its own protection against
transient’s surges and discharges are
being provided by the line circuit
protection network. The Splitter
contains no specific circuitry for
this purpose.
Storage
Device storage temperature should be
within the range - 45º C / + 70º C.
Mechanical Layout
The dimensions of Splitter itself are
suitable to be able to be installed
easily on the layout of ADSL Sub-rack.
![]() |
![]() |